A hydrostatic drive that will not find neutral, will not pull, or only works in one direction is usually telling you where the fault is. This guide works backwards from the symptom to the circuit that causes it — pump control, charge circuit, multifunction valves, or the motor itself.
Work down each list in the order given. The first two or three items cover most failures, and they cost nothing to check. Only move to the components after the pressures and the control signal have been measured.
One test settles a lot of cases: swap the two multifunction valves left for right. If the fault changes direction with them, the valve is the problem. If nothing changes, the fault is upstream in the control signal or downstream in the motor.
1. Difficult or impossible to find neutral
- Faulty input signal from the pump control source to the control module. Check the input control signal; repair or replace the related parts if necessary.
- Faulty control linkage or a blocked control orifice in the pump displacement control module. Adjust or repair the control module; replace it if necessary.
- Multifunction valve leakage. Swap the two multifunction valves; if the system fault changes direction, replace the damaged valve.
2. System overheating
- Low oil level in the tank. Add hydraulic oil to the correct level.
- Insufficient radiator or cooler capacity. Check the air flow and the temperature through the radiator; clean, repair or replace it.
- Low charge pressure. Measure charge pressure; check and adjust the charge pressure relief valve, replace it if necessary; or repair the charge pump if its leakage is excessive.
- High vacuum in the charge pump suction line. Check the vacuum; if it is too high, inspect the suction filter and replace it; check the diameter, length and fittings of the suction line.
- System relief valve set too low. Check the high-pressure relief valve or pressure-limiter setting; adjust or replace the multifunction valve.
- Excessive internal leakage in the motor. Block the flush valve spool, or without a flush valve observe the motor case drain flow; if it is too high, replace the motor.
- System pressure too high. Measure system pressure; reduce the load if necessary.
3. System works in one direction only
- Faulty input signal to the control module. Check the input control signal; repair or replace it if necessary.
- Control linkage fault or blocked orifice. Adjust or repair the control module; replace it if necessary.
- Faulty pressure limiter, high-pressure relief valve or charge check valve. Swap the multifunction valves; if the fault changes direction, replace the damaged one.
- Shuttle valve spool of the flush valve stuck, causing low charge pressure in one direction. Measure charge pressure in forward and in reverse; check or repair the circuit flush valve.
4. System does not work in either direction
- Low oil level. Add oil.
- Faulty input signal. Check the signal; repair or replace it.
- Control linkage or orifice fault. Adjust or repair the control module, or replace it.
- Bypass valve open. Close the bypass valve; replace the multifunction valve if it is damaged.
- Low charge pressure at neutral. Measure charge pressure at neutral; if it is low, adjust the charge relief valve.
- Charge pressure drops excessively when off neutral. Check the flush relief valve or the system relief valve setting; adjust or replace; if neither is at fault, check the charge pump.
- Charge relief valve faulty or set too low. Adjust or replace it.
- Clogged charge pump suction filter. Inspect and replace it.
- Charge pump failure. Repair or replace it.
- Low system pressure caused by a faulty multifunction valve. Repair or replace it.
5. Low motor output torque
- Low pressure at the motor inlet, because the multifunction valve is set too low. Measure the inlet pressure; increase the valve setting if necessary.
- Variable motor stuck at minimum displacement. Check the control supply pressure or repair the displacement control module; check for a blocked orifice.
- Excessive internal leakage. Check the seals — O-rings, gaskets and fittings; repair or replace the components that leak excessively.
6. Insufficient motor output speed
- Low oil level. Add oil.
- Incorrect pump output flow, with the swashplate off position. Measure the pump flow and speed; make sure the pump reaches full displacement.
- Variable motor displacement control failure. Check whether the displacement adjustment responds; if it does not, repair or replace the control module.
- Excessive internal leakage. Check the seals; repair or replace the components.
7. System noise or vibration
- Low oil level causing cavitation. Add oil.
- Air in the system. Look for foam in the tank and leaks in the suction line; let the oil settle after the repair; run the system at low speed repeatedly to exchange the oil.
- High suction vacuum from a clogged filter or an undersized suction line. Check and replace the filter; check the suction line diameter.
- Loose coupling. Replace the coupling, or the pump or motor.
- Misaligned shafts. Realign the shafts.
8. System slow to respond
- Low oil level. Add oil.
- Improper pressure setting of the multifunction valve. Adjust or replace it.
- High suction vacuum. Measure the vacuum; replace the suction filter if it is too high.
- Low engine speed. Adjust the engine speed.
- Incorrect charge and control pressures. Measure them and correct if necessary.
- Excessive internal leakage. Check the seals — O-rings, gaskets and fittings.
The five terms this guide uses. Charge pressure — the low-pressure supply that keeps the closed loop full and feeds the control circuit. Multifunction valve — the block that combines high-pressure relief, charge check and bypass on each side of the loop. Swashplate — the tilting plate that sets pump displacement. Flush valve — the spool that dumps a small flow from the low-pressure side to the case and carries heat out of the loop. Case drain — leakage returning from pump or motor to tank; its flow rate is the standard internal-leakage test.